DreamScreen ProSilence FluxCore Clip

DECOUPLE THE STRUCTURE.
STOP THE VIBRATION.

A patent-pending multi-density isolation clip engineered to reduce mechanical vibration transmission through walls and ceilings — with particular emphasis on the low-frequency region where conventional resilient mounting systems are often least effective.

48.4 kg
Permissible ceiling load / clip
Safety factor 2.5
34 mm
Build-out
B-s1,d0
FluxCore fire performance
Multi
Density core
WALL + CEILING
Installation
Product & project support

Plan it into your room.

Explore the indicative price and discuss the complete installation with your DreamScreen partner.

Indicative retail priceEUR 13EUR · excluding VAT / taxes, freight and installation

No online checkout. Your DreamScreen partner confirms the configuration, availability, local pricing and delivery.

THE FLUXCORE PRINCIPLE

Control how vibration energy
moves through the structure.

Sound insulation is not only about adding mass. Low-frequency energy can travel efficiently through rigid mechanical connections between the isolated structure and the building around it.

FluxCore introduces a controlled mechanical spring between these structures. By combining materials with different elastic properties, the core is designed to provide effective decoupling across a wider frequency range while retaining the mechanical capacity required for heavy wall and ceiling systems.

PATENT-PENDING MULTI-DENSITY CORE

One clip.
Multiple mechanical behaviours.

The FluxCore decoupler combines elastomeric materials with different mechanical characteristics instead of relying on one uniformly stiff isolation element.

Low frequency

Soft inner core

Allows greater spring movement and helps lower the mechanical resonance of the decoupled system.

Higher frequency

Controlled damping

Additional material characteristics help dissipate vibration energy over a broader frequency range.

Mechanical

High capacity

Designed to carry heavy board constructions while retaining useful elastic movement.

System

Energy control

Mechanical energy is attenuated before it can propagate into the surrounding building structure.

MASS + DECOUPLING + DAMPING

Sound isolation is a system.

FluxCore is not intended to work as an isolated component. Its performance depends on the interaction between mass, mechanical decoupling, cavity design and internal damping.

Illustration of mass, decoupling and damping in the ProSilence FluxCore system

At low frequencies the mechanical decoupling system and structural mass become particularly important, while damping compounds contribute primarily through the mid- and high-frequency region.

LOW-FREQUENCY DECOUPLING

Bass is where decoupling
becomes difficult.

Conventional resilient mounting products can behave relatively stiffly. If the mechanical resonance of the complete construction sits too high, bass energy can continue to couple efficiently through the assembly.

FluxCore is designed around a substantially more compliant spring element, helping move the resonance of the decoupled structure downward and improving isolation in the low-frequency region.

TESTED FIRE PERFORMANCE

B-s1,d0.
Engineered beyond vibration control.

The FluxCore material system has been independently tested for reaction to fire and achieved B-s1,d0 according to EN 13501-1:2018.

This represents a high level of fire performance for an elastomeric vibration-isolation system, combining limited contribution to fire, very low smoke production and no flaming droplets or particles.

B
Reaction to fire

High reaction-to-fire classification under EN 13501-1.

s1
Smoke production

Very limited smoke production during the classification test.

d0
Flaming droplets

No flaming droplets or particles within the classification criteria.

Fire-performance data shown here is based on testing of the FluxCore elastomeric system according to EN 13823 and EN ISO 11925-2. Formal product-specific classification should be referenced against the applicable test documentation.

FLUXCORE VS. CONVENTIONAL RESILIENT SYSTEMS

Lower resonance.
Better bass control.

The core difference is mechanical compliance. FluxCore is designed as a loaded spring system rather than a relatively rigid spacer between the structural frame and the isolated surface.

Comparison between ProSilence FluxCore and conventional resilient isolation

Conceptual comparison illustrating the low-frequency behaviour of a spring-decoupled construction compared with a more rigid isolation system.

MECHANICAL CAPACITY / SINTEF TEST BASIS

Soft where it matters.
Strong where it counts.

FluxCore combines a compliant isolation core with a load-bearing steel connection. Laboratory failure load, permissible mechanical load and acoustic working load are different figures: the approximately 150 kg failure result is not a load to use in an installation.

≈150 kg
Mean laboratory failure load

Ceiling: 1,503.5 N. Wall: 1,485.5 N. Approximately 150 kg mass equivalent per tested connection. Not a working or hanging load.

48.4 kg
Permissible ceiling load

475 N per clip, including statistical reduction and a safety factor of 2.5. Approximately 50 kg in rounded communication; use 475 N for design. Not an acoustic optimum.

350 N
Wall functional limit

About 35.7 kg mass equivalent per clip. The report recommends this limit for intended decoupling function, below the strength-based wall value of 543.5 N.

Source: SINTEF PR26-00288, 22 September 2026. The calculation first reduces the mean failure load for variation between samples, then applies the 2.5 safety factor; simply dividing 150 kg by 2.5 misses that reduction. Results apply to the tested clip, channel, fixings and prescribed tightening. See the mechanical test basis at ProSilence.com.

ACOUSTIC WORKING LOAD / SEPARATE PLANNING GUIDANCE

Plan for the spring.
Keep strength in reserve.

Our normal wall dead-load planning target is at most approximately 25 kg per clip. For heavier ceilings, approximately 29 kg per clip is the proposed normal target; 35 kg per clip is a provisional upper planning boundary, subject to verification for the specified installation. These are ProSilence planning values, not a SINTEF-certified acoustic optimum or a measured acoustic maximum.

The provisional 35 kg ceiling boundary is based on our interpretation of the H5 compression curve, assuming a 5 mm local black-core thickness. Actual core geometry and prescribed installation preload must be checked. Acoustic performance at the 475 N ceiling strength limit was not assessed in the mechanical test.

Two layers of 12.5 mm gypsum-fibre board with damping compound are our normal recommendation. A single layer is also possible with suitable board support; no fixed minimum working load per wall clip has been established. Do not add weight simply to reach a planning target.

Include boards, compound, finishes and equipment in the total load. Loudspeaker and equipment mounts need project-specific load spreading, additional local clips and checks of brackets, anchors and actual reactions. More clips do not automatically share load equally. The difference up to the strength limit is not a rated equipment allowance. Read the load-planning guidance at ProSilence.com.

APPLICATIONS

Made for structures
where vibration matters.

FluxCore Clip can be used in both wall and ceiling constructions and is particularly relevant where substantial low-frequency or structure-borne energy must be controlled.

Home cinema

Reduce transmission of powerful subwoofer and loudspeaker energy.

Recording studio

Mechanically separate critical walls and ceilings from the host structure.

Technical rooms

Reduce vibration transmission from mechanically active spaces.

Heavy ceilings

High capacity provides additional design margin for substantial suspended constructions.

INSTALLATION

Simple components.
Precise loading.

The steel mounting component is installed first. The FluxCore isolation element is then inserted together with the recommended steel profile before the board construction is attached.

ProSilence FluxCore Clip installation

Use the specified clip, channel and fixings, and follow the prescribed installation tightening. The load assessment depends on that assembly and preload. Do not loosen screws to obtain more spring movement or to reproduce a compression test performed without installation preload. Follow the current ProSilence installation instructions.

SEE DECOUPLING IN ACTION

Vibration needs somewhere to go.

This demonstration shows the basic mechanical principle behind ProSilence decoupling and how a compliant isolation element prevents vibration from travelling directly into the surrounding structure.

TECHNICAL DATA

Main specifications

Technology Patent-pending multi-density mechanical decoupler
Recommended application Decoupled walls and ceilings
Mean laboratory failure loadCeiling: 1,503.5 N. Wall: 1,485.5 N. Approximately 150 kg mass equivalent per tested connection. Not working loads.
Permissible mechanical load — ceiling475 N per clip (approximately 48.4 kg mass equivalent), including statistical reduction and safety factor 2.5. Approximately 50 kg is a rounded description, not a higher design limit.
Mechanical assessment — wall543.5 N strength-based value with safety factor 2.5; the report recommends limiting wall load to 350 N (approximately 35.7 kg) for intended decoupling function.
Acoustic working-load planningNormal wall dead-load target: at most approximately 25 kg per clip. Heavier ceilings: approximately 29 kg normal target; 35 kg provisional upper planning boundary, subject to installation verification. ProSilence model-based guidance, not a SINTEF-certified acoustic optimum or a measured acoustic maximum. No fixed minimum wall working load is established.
Load basis and installationSINTEF PR26-00288, 22 September 2026. Use the tested clip, channel, fixings and prescribed tightening. Include all lining and equipment weight and verify local reactions. Strength reserve is not an automatic equipment allowance. Full load definitions and qualifications at ProSilence.com.
Build-out Approx. 34 mm
Recommended board construction Two layers of 12.5 mm gypsum-fibre board with damping compound are normally recommended. A single layer is possible with suitable board support; no fixed minimum working load per wall clip is established.
Heavy construction capability Designed for constructions with up to four heavy board layers where correctly engineered
Core Multi-density elastomeric isolation system
Fire performance FluxCore elastomeric system tested to EN 13501-1:2018, B-s1,d0
Primary design objective Wide-band mechanical decoupling with improved low-frequency behaviour
DOCUMENTATION

Design the complete structure.

For optimum sound isolation, clip spacing, structural mass, cavity depth, board configuration and flanking transmission all need to be considered as part of the complete construction.

Find a dealer or contact DreamScreen Mechanical load documentation Installation manual
DREAMSCREEN PROSILENCE FLUXCORE

Mass stops sound.
FluxCore breaks the connection.

For demanding cinema, studio and sound-isolation projects, contact us for help designing the complete ProSilence construction.

Find a dealer or contact DreamScreen

YouTube video. Playback connects to YouTube.